regulator: cp9314: Adds regulator_get_error_flags support
Adds a handler to check error flag bits. This should be called by applications that call regulator_enable and receive -EINVAL as a return. Signed-off-by: Ricardo Rivera-Matos <rriveram@opensource.cirrus.com>
This commit is contained in:
parent
f9ce311855
commit
4928f3b7ff
|
@ -66,6 +66,16 @@ LOG_MODULE_REGISTER(CP9314, CONFIG_REGULATOR_LOG_LEVEL);
|
|||
#define CP9314_MODE_2TO1 1
|
||||
#define CP9314_MODE_3TO1 2
|
||||
|
||||
#define CP9314_REG_FLT_FLAG 0x12
|
||||
#define CP9314_VIN_OVP_FLAG BIT(1)
|
||||
#define CP9314_VOUT_OVP_FLAG BIT(0)
|
||||
|
||||
#define CP9314_REG_COMP_FLAG0 0x2A
|
||||
#define CP9314_IIN_OCP_FLAG BIT(4)
|
||||
|
||||
#define CP9314_REG_COMP_FLAG1 0x2C
|
||||
#define CP9314_VIN2OUT_OVP_FLAG BIT(0)
|
||||
|
||||
#define CP9314_REG_LION_CFG_1 0x31
|
||||
#define CP9314_LB2_DELTA_CFG_1 GENMASK(7, 5)
|
||||
|
||||
|
@ -232,6 +242,47 @@ static struct cp9314_reg_patch otp_1_patch[3] = {
|
|||
{CP9314_REG_TSBAT_CTRL, CP9314_LB1_STOP_PHASE_SEL, CP9314_LB1_STOP_PHASE_SEL},
|
||||
};
|
||||
|
||||
static int regulator_cp9314_get_error_flags(const struct device *dev,
|
||||
regulator_error_flags_t *flags)
|
||||
{
|
||||
const struct regulator_cp9314_config *config = dev->config;
|
||||
uint8_t val[3];
|
||||
int ret;
|
||||
|
||||
*flags = 0U;
|
||||
|
||||
ret = i2c_reg_read_byte_dt(&config->i2c, CP9314_REG_FLT_FLAG, &val[0]);
|
||||
if (ret < 0) {
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (FIELD_GET(CP9314_VIN_OVP_FLAG, val[0]) || FIELD_GET(CP9314_VOUT_OVP_FLAG, val[0])) {
|
||||
*flags |= REGULATOR_ERROR_OVER_VOLTAGE;
|
||||
}
|
||||
|
||||
ret = i2c_reg_read_byte_dt(&config->i2c, CP9314_REG_COMP_FLAG0, &val[1]);
|
||||
if (ret < 0) {
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (FIELD_GET(CP9314_IIN_OCP_FLAG, val[1])) {
|
||||
*flags |= REGULATOR_ERROR_OVER_CURRENT;
|
||||
}
|
||||
|
||||
ret = i2c_reg_read_byte_dt(&config->i2c, CP9314_REG_COMP_FLAG1, &val[2]);
|
||||
if (ret < 0) {
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (FIELD_GET(CP9314_VIN2OUT_OVP_FLAG, val[2])) {
|
||||
*flags |= REGULATOR_ERROR_OVER_VOLTAGE;
|
||||
}
|
||||
|
||||
LOG_DBG("FLT_FLAG = 0x%x, COMP_FLAG0 = 0x%x, COMP_FLAG1 = 0x%x", val[0], val[1], val[2]);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int regulator_cp9314_disable(const struct device *dev)
|
||||
{
|
||||
const struct regulator_cp9314_config *config = dev->config;
|
||||
|
@ -550,6 +601,7 @@ static int regulator_cp9314_init(const struct device *dev)
|
|||
static const struct regulator_driver_api api = {
|
||||
.enable = regulator_cp9314_enable,
|
||||
.disable = regulator_cp9314_disable,
|
||||
.get_error_flags = regulator_cp9314_get_error_flags,
|
||||
};
|
||||
|
||||
#define REGULATOR_CP9314_DEFINE(inst) \
|
||||
|
|
Loading…