docs: safety: Add safety documentation
Add the safety documentation to the Zephyr documentation tree. Starts with the safety overview which describes the general goals for the safety in zephyr and introduces a process overview how a safety certification can be achieved in the zephyr project. Signed-off-by: Simon Hein <Shein@baumer.com>
This commit is contained in:
parent
8d15cf2829
commit
e908f88920
|
@ -23,3 +23,4 @@ Zephyr Project Documentation
|
|||
contribute/index.rst
|
||||
project/index.rst
|
||||
security/index.rst
|
||||
safety/index.rst
|
||||
|
|
|
@ -111,6 +111,7 @@ Sections
|
|||
contribute/index.rst
|
||||
project/index.rst
|
||||
security/index.rst
|
||||
safety/index.rst
|
||||
samples/index.rst
|
||||
boards/index.rst
|
||||
releases/index.rst
|
||||
|
|
1
doc/safety/images/zephyr-safety-process.svg
generated
Normal file
1
doc/safety/images/zephyr-safety-process.svg
generated
Normal file
File diff suppressed because one or more lines are too long
After Width: | Height: | Size: 31 KiB |
13
doc/safety/index.rst
Normal file
13
doc/safety/index.rst
Normal file
|
@ -0,0 +1,13 @@
|
|||
.. _safety_section:
|
||||
|
||||
Safety
|
||||
########
|
||||
|
||||
These documents describe the processes, developer guidelines and requirements
|
||||
for ensuring safety is addressed within the Zephyr project.
|
||||
|
||||
.. toctree::
|
||||
:maxdepth: 1
|
||||
:glob:
|
||||
|
||||
safety_overview.rst
|
264
doc/safety/safety_overview.rst
Normal file
264
doc/safety/safety_overview.rst
Normal file
|
@ -0,0 +1,264 @@
|
|||
.. _safety_overview:
|
||||
|
||||
Zephyr Safety Overview
|
||||
########################
|
||||
|
||||
Introduction
|
||||
************
|
||||
|
||||
This document is the safety documentation providing an overview over the safety-relevant activities
|
||||
and what the Zephyr Project and the Zephyr Safety Working Group / Committee try to achieve.
|
||||
|
||||
This overview is provided for people who are interested in the functional safety development part
|
||||
of the Zephyr RTOS and project members who want to contribute to the safety aspects of the
|
||||
project.
|
||||
|
||||
Overview
|
||||
********
|
||||
|
||||
In this section we give the reader an overview of what the general goal of the safety certification
|
||||
is, what standard we aim to achieve and what quality standards and processes need to be implemented
|
||||
to reach such a safety certification.
|
||||
|
||||
Safety Document update
|
||||
**********************
|
||||
|
||||
This document is a living document and may evolve over time as new requirements, guidelines, or
|
||||
processes are introduced.
|
||||
|
||||
#. Changes will be submitted from the interested party(ies) via pull requests to the Zephyr
|
||||
documentation repository.
|
||||
|
||||
#. The Zephyr Safety Committee will review these changes and provide feedback or acceptance of
|
||||
the changes.
|
||||
|
||||
#. Once accepted, these changes will become part of the document.
|
||||
|
||||
General safety scope
|
||||
********************
|
||||
|
||||
The general scope of the Safety Committee is to achieve a certification for the `IEC 61508
|
||||
<https://en.wikipedia.org/wiki/IEC_61508>`__ standard and the Safety Integrity Level (SIL) 3 /
|
||||
Systematic Capability (SC) 3 for a limited source scope (see certification scope TBD). Since the
|
||||
code base is pre-existing, we use the route 3s/1s approach defined by the IEC 61508 standard.
|
||||
|
||||
Route 3s
|
||||
*Assessment of non-compliant development. Which is basically the route 1s with existing
|
||||
sources.*
|
||||
|
||||
Route 1s
|
||||
*Compliant development. Compliance with the requirements of this standard for the avoidance and
|
||||
control of systematic faults in software.*
|
||||
|
||||
Summarization IEC 61508 standard
|
||||
================================
|
||||
|
||||
The IEC 61508 standard is a widely recognized international standard for functional safety of
|
||||
electrical, electronic, and programmable electronic safety-related systems. Here's an overview of
|
||||
some of the key safety aspects of the standard:
|
||||
|
||||
#. **Hazard and Risk Analysis**: The IEC 61508 standard requires a thorough analysis of potential
|
||||
hazards and risks associated with a system in order to determine the appropriate level of safety
|
||||
measures needed to reduce those risks to acceptable levels.
|
||||
|
||||
#. **Safety Integrity Level (SIL)**: The standard introduces the concept of Safety Integrity Level
|
||||
(SIL) to classify the level of risk reduction required for each safety function. The higher the
|
||||
SIL, the greater the level of risk reduction required.
|
||||
|
||||
#. **System Design**: The IEC 61508 standard requires a systematic approach to system design that
|
||||
includes the identification of safety requirements, the development of a safety plan, and the
|
||||
use of appropriate safety techniques and measures to ensure that the system meets the required
|
||||
SIL.
|
||||
|
||||
#. **Verification and Validation**: The standard requires rigorous testing and evaluation of the
|
||||
safety-related system to ensure that it meets the specified SIL and other safety requirements.
|
||||
This includes verification of the system design, validation of the system's functionality, and
|
||||
ongoing monitoring and maintenance of the system.
|
||||
|
||||
#. **Documentation and Traceability**: The IEC 61508 standard requires a comprehensive
|
||||
documentation process to ensure that all aspects of the safety-related system are fully
|
||||
documented and that there is full traceability from the safety requirements to the final system
|
||||
design and implementation.
|
||||
|
||||
Overall, the IEC 61508 standard provides a framework for the design, development, and
|
||||
implementation of safety-related systems that aims to reduce the risk of accidents and improve
|
||||
overall safety. By following the standard, organizations can ensure that their safety-related
|
||||
systems are designed and implemented to the highest level of safety integrity.
|
||||
|
||||
Quality
|
||||
*******
|
||||
|
||||
Quality is a mandatory expectation for software across the industry. The code base of the project
|
||||
must achieve various software quality goals in order to be considered an auditable code base from a
|
||||
safety perspective and to be usable for certification purposes. But software quality is not an
|
||||
additional requirement caused by functional safety standards. Functional safety considers quality
|
||||
as an existing pre-condition and therefore the "quality managed" status should be pursued for any
|
||||
project regardless of the functional safety goals. The following list describes the quality goals
|
||||
which need to be reached to achieve an auditable code base:
|
||||
|
||||
1. Basic software quality standards
|
||||
|
||||
a. :ref:`coding_guidelines` (including: static code analysis, coding style, etc.)
|
||||
b. Requirements and requirements tracing
|
||||
c. Test coverage
|
||||
|
||||
2. Software architecture design principles
|
||||
|
||||
a. Layered architecture model
|
||||
b. Encapsulated components
|
||||
c. Encapsulated single functionality (if not fitable and manageable in safety)
|
||||
|
||||
Basic software quality standards - Safety view
|
||||
==============================================
|
||||
|
||||
In this chapter the Safety Committee describes why they need the above listed quality goals as
|
||||
pre-condition and what needs to be done to achieve an auditable code base from the safety
|
||||
perspective. Generally speaking, it can be said that all of these quality measures regarding safety
|
||||
are used to minimize the error rate during code development.
|
||||
|
||||
Coding Guidelines
|
||||
-----------------
|
||||
|
||||
The coding guidelines are the basis to a common understanding and a unified ruleset and development
|
||||
style for industrial software products. For safety the coding guidelines are essential and have
|
||||
another purpose beside the fact of a unified ruleset. It is also necessary to prove that the
|
||||
developers follow a unified development style to prevent **systematic errors** in the process of
|
||||
developing software and thus to minimize the overall **error rate** of the complete software
|
||||
system.
|
||||
|
||||
Also the **IEC 61508 standard** sets a pre-condition and recommendation towards the use of coding
|
||||
standards / guidelines to reduce likelihood of errors.
|
||||
|
||||
Requirements and requirements tracing
|
||||
-------------------------------------
|
||||
|
||||
Requirements and requirement management are not only important for software development, but also
|
||||
very important in terms of safety. On the one hand, this specifies and describes in detail and on a
|
||||
technical level what the software should do, and on the other hand, it is an important and
|
||||
necessary tool to verify whether the described functionality is implemented as expected. For this
|
||||
purpose, tracing the requirements down to the code level is used. With the requirements management
|
||||
and tracing in hand, it can now be verified whether the functionality has been tested and
|
||||
implemented correctly, thus minimizing the systematic error rate.
|
||||
|
||||
Also the IEC 61508 standard highly recommends (which is like a must-have for the certification)
|
||||
requirements and requirements tracing.
|
||||
|
||||
Test coverage
|
||||
-------------
|
||||
|
||||
A high test coverage, in turn, is evidence of safety that the code conforms precisely to what it
|
||||
was developed for and does not execute any unforeseen instructions. If the entire code is tested
|
||||
and has a high (ideally 100%) test coverage, it has the additional advantage of quickly detecting
|
||||
faulty changes and further minimizing the error rate. However, it must be noted that different
|
||||
requirements apply to safety for test coverage, and various metrics must be considered, which are
|
||||
prescribed by the IEC 61508 standard for the SIL 3 / SC3 target. The following must be fulfilled,
|
||||
among other things:
|
||||
|
||||
* Structural test coverage (entry points) 100%
|
||||
* Structural test coverage (statements) 100%
|
||||
* Structural test coverage (branches) 100%
|
||||
|
||||
If the 100% cannot be reached (e.g. statement coverage of defensive code) that part needs to be
|
||||
described and justified in the documentation.
|
||||
|
||||
Software architecture design principles
|
||||
=======================================
|
||||
|
||||
To create and maintain a structured software product it is also necessary to consider individual
|
||||
software architecture designs and implement them in accordance with safety standards because some
|
||||
designs and implementations are not reasonable in safety, so that the overall software and code
|
||||
base can be used as auditable code. However, most of these software architecture designs have
|
||||
already been implemented in the Zephyr project and need to be verified by the Safety Committee /
|
||||
Safety Working Group and the safety architect.
|
||||
|
||||
Layered architecture model
|
||||
--------------------------
|
||||
|
||||
The **IEC 61508 standard** strongly recommends a modular approach to software architecture. This
|
||||
approach has been pursued in the Zephyr project from the beginning with its layered architecture.
|
||||
The idea behind this architecture is to organize modules or components with similar functionality
|
||||
into layers. As a result, each layer can be assigned a specific role in the system. This model has
|
||||
the advantage in safety that interfaces between different components and layers can be shown at a
|
||||
very high level, and thus it can be determined which functionalities are safety-relevant and can be
|
||||
limited. Furthermore, various analyses and documentations can be built on top of this architecture,
|
||||
which are important for certification and the responsible certification body.
|
||||
|
||||
Encapsulated components
|
||||
-----------------------
|
||||
|
||||
Encapsulated components are an essential part of the architecture design for safety at this point.
|
||||
The most important aspect is the separation of safety-relevant components from non-safety-relevant
|
||||
components, including their associated interfaces. This ensures that the components have no
|
||||
**repercussions** on other components.
|
||||
|
||||
Encapsulated single functionality (if not reasonable and manageable in safety)
|
||||
------------------------------------------------------------------------------
|
||||
|
||||
Another requirement for the overall system and software environment is that individual
|
||||
functionalities can be disabled within components. This is because if a function is absolutely
|
||||
unacceptable for safety (e.g. complete dynamic memory management), then these individual
|
||||
functionalities should be able to be turned off. The Zephyr Project already offers such a
|
||||
possibility through the use of Kconfig and its flexible configurability.
|
||||
|
||||
Processes and workflow
|
||||
**********************
|
||||
|
||||
.. figure:: images/zephyr-safety-process.svg
|
||||
:align: center
|
||||
:alt: Safety process and workflow overview
|
||||
:figclass: align-center
|
||||
|
||||
Safety process and workflow overview
|
||||
|
||||
The diagram describes the rough process defined by the Safety Committee to ensure safety in the
|
||||
development of the Zephyr project. To ensure understanding, a few points need to be highlighted and
|
||||
some details explained regarding the role of the safety architect and the role of the safety
|
||||
committee in the whole process. The diagram only describes the paths that are possible when a
|
||||
change is related to safety.
|
||||
|
||||
#. On the main branch, the safety scope of the project should be identified, which typically
|
||||
represents a small subset of the entire code base. This subset should then be made auditable
|
||||
during normal development on “main”, which means that special attention is paid to quality goals
|
||||
(`Quality`_) and safety processes within this scope. The Safety Architect works alongside the
|
||||
Technical Steering Committee (TSC) in this area, monitoring the development process to ensure
|
||||
that the architecture meets the safety requirements.
|
||||
|
||||
#. At this point, the safety architect plays an increasingly important role. For PRs/issues that
|
||||
fall within the safety scope, the safety architect should ideally be involved in the discussions
|
||||
and decisions of minor changes in the safety scope to be able to react to safety-relevant
|
||||
changes that are not conformant. If a pull request or issue introduces a significant and
|
||||
influential change or improvement that requires extended discussion or decision-making, the
|
||||
safety architect should bring it to the attention of the Safety Committee or the Technical
|
||||
Steering Committee (TSC) as appropriate, so that they can make a decision on the best course of
|
||||
action.
|
||||
|
||||
#. This section describes the certification side. At this point, the code base has to be in an
|
||||
"auditable" state, and ideally no further changes should be necessary or made to the code base.
|
||||
There is still a path from the main branch to this area. This is needed in case a serious bug or
|
||||
important change is found or implemented on the main branch in the safety scope, after the LTS
|
||||
and the auditable branch were created. In this case, the Safety Committee, together with the
|
||||
safety architect, must decide whether this bug fix or change should be integrated into the LTS
|
||||
so that the bug fix or change could also be integrated into the auditable branch. This
|
||||
integration can take three forms: First either as only a code change or second as only an update
|
||||
to the safety documentation or third as both.
|
||||
|
||||
#. This describes the necessary safety process required for certification itself. Here, the final
|
||||
analyses, tests, and documents are created and conducted which must be created and conducted
|
||||
during the certification, and which are prescribed by the certifying authority and the standard
|
||||
being certified. If the certification body approves everything at this stage and the safety
|
||||
process is completed, a safety release can be created and published.
|
||||
|
||||
#. This transition from the auditable branch to the main branch should only occur in exceptional
|
||||
circumstances, specifically when something has been identified during the certification process
|
||||
that needs to be quickly adapted on the “auditable” branch in order to obtain certification. In
|
||||
order to prevent this issue from arising again during the next certification, there needs to be
|
||||
a path to merge these changes back into the main branch so that they are not lost, and to have
|
||||
them ready for the next certification if necessary.
|
||||
|
||||
.. important::
|
||||
Safety should not block the project and minimize the room to grow in any way.
|
||||
|
||||
.. important::
|
||||
**TODO:** Find and define ways, guidelines and processes which minimally impact the daily work
|
||||
of the maintainers, reviewers and contributors and also the safety architect itself.
|
||||
But which are also suitable for safety.
|
Loading…