Let's use sock->is_connected to check whether we need to clean up
the modem's socket. It may have already been closed via URC.
Signed-off-by: Michael Scott <mike@foundries.io>
SARA-R4 AT command manual states +USOCO has a max timeout of 120s.
Let's use that instead of the default 10s command timeout.
Signed-off-by: Michael Scott <mike@foundries.io>
The SARA R412M requires manual activation of the PDP context. It also
reports RSSI instead of RSRP when on 2G. An off-by-one in the RSRP
calculation was also fixed in this commit.
Signed-off-by: Göran Weinholt <goran.weinholt@endian.se>
The u-blox SARA modems have the ability to output the network status
on a GPIO pin. This can be used to light up a LED when the modem is
connected to the network.
Signed-off-by: Göran Weinholt <goran.weinholt@endian.se>
The U2 modem will sometimes not power off even if we have given it the
signal to do so. We now signal it continually until the modem
indicates that power is off with VINT=0.
Signed-off-by: Göran Weinholt <goran.weinholt@endian.se>
This fixes two problems in modem_reset():
- mdata.net_iface is used without checking that it is valid.
Now, we validate mdata_net_iface before usage, and give a warning
if it was not set.
- if the modem does not perform network registration within the
given time of 20s, in the previous implementation the driver
gave up.
Now, the driver disables RF for a second, enables it again and
gives the modem another 20s to register. This has been seen
to help in roaming situations.
Tested on Sara R4.
Signed-off-by: Hans Wilmers <hans@wilmers.no>
- limit max. number of bytes when sending to socket
The number of bytes sent to a socket in one transaction
is limited to 512 in HEX mode (Sara-R4), and to 1024
otherwise. This corresponds to numbers given in the
manual for ublox cellular modems.
- report number of bytes actually sent, as reported by modem
After writing data to a socket, we now return the number of
bytes actually written, as reported by the modem.
Signed-off-by: Hans Wilmers <hans@wilmers.no>
In order to still process 128 bytes at a time, let's add 1 to the
length of match_buf which will be used to store a NUL char when
the match_buf is at max size (size - 1).
Otherwise we're processing 127 bytes at a time which is inefficient
compared to the data buffer sizes in net_buf.
Signed-off-by: Michael Scott <mike@foundries.io>
SARA-R4 modem supports offloaded DNS via AT+UDNSRN command.
Let's implement it.
NOTE! On SARA-R4 a new firmware *IS* required to support this feature:
L0.0.00.00.05.08 [Apr 17 2019 19:34:02]
Signed-off-by: Michael Scott <mike@foundries.io>
Managing the interface up / down events from driver code (as opposed
to L2 layers) has been an issue for quite some time. There are
race conditions which result in data aborts (referencing NULL
iface or NULL iface->if_dev) or ends up breaking ASSERT checks for
non-NULL iface.
Let's remove the handling for now and come up with something better
when a user actually needs it.
Signed-off-by: Michael Scott <mike@foundries.io>
In offload_recvfrom(), if we end up calling modem_cmd_send(),
then we should always wait for the results. We've already
checked for MSG_DONTWAIT and made sure that there is data ready.
We just need to get it from the modem buffer at this point.
Signed-off-by: Michael Scott <mike@foundries.io>
Users may be waiting for data via socket recv() function. We
notify them that data is ready when URC is received from modem.
Once unblocked, we read the data from the modem buffer which
is handled via on_cmd_sockread_common(). At this point, we
don't need to unblock waiting users again.
Signed-off-by: Michael Scott <mike@foundries.io>
The hex_to_binary() function is incorrectly assuming all buffers
passed to recv() will have an additinal byte for storing a NUL
terminating char. This should be optional as MQTT library uses
exact sized buffers for parsing socket data.
Signed-off-by: Michael Scott <mike@foundries.io>
The send_socket_data() is incorrectly sending 0 as successful result.
The socket APIs require the number of bytes sent to be returned.
Signed-off-by: Michael Scott <mike@foundries.io>
After startup ublox-sara-r4 code sets the MDM_POWER signal to input
using a deprecated configuration macro. This was the only use of the
modem context API to configure a pin.
Refactor the API to not take the flags as an input but instead select
between the flags to be used when the pin is active and a disconnected
state. Use this API instead of a separate direct configure call when
initializing the modem pins.
Signed-off-by: Peter Bigot <peter.bigot@nordicsemi.no>
Convert to the new API using raw access, since it's a common access
layer shared by multiple (right now only ublox-sara-r4) modems.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
This adds support for SARA-U2 modems. They have different timings on
the PWR_ON pin, don't support AT+CESQ and require a manual GPRS
connection setup.
The VINT pin is used as a more reliable and faster way to power on the
modem.
Based on work by Göran Weinholt <goran.weinholt@endian.se>
Signed-off-by: Michael Scott <mike@foundries.io>
Let's convert the SARA modem to use the more generic modem context
layers so that we don't maintain a lot of what should be shared code.
This conversion includes:
- modem context as the helper umbrella
- uart modem interface layer
- generic command handler layer
- modem socket helper
- move from net_context offload API to socket offload API
Signed-off-by: Michael Scott <mike@foundries.io>
move gpio.h to drivers/gpio.h and
create a shim for backward-compatibility.
No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.
Related to #16539
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
Move modem_receiver.h to the driver directory. No other users in the
tree and it is a private header.
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
Change code from using now deprecated DT_<COMPAT>_<INSTANCE>_<PROP>
defines to using DT_INST_<INSTANCE>_<COMPAT>_<PROP>.
Signed-off-by: Kumar Gala <kumar.gala@linaro.org>
The u-blox SARA-R4 modem modules are Ultra-compact LTE Cat
M1 / NB1 ready:
- Configurable with a single hardware version
- Flexible mode selection as LTE Cat M1, LTE Cat NB1, EGPRS -
only/preferred
- Low power consumption and longer battery life
- Extended range in buildings, basements, and with NB1,
underground
This driver introduces support for basic AT commands to
query modem information as well as socket connection
for TCP/UDP communication.